Lenovo ThinkServer TD200 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Lenovo ThinkServer TD200. Lenovo ThinkServer TD200 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Installation and User Guide

Installation and User GuideThinkServer TD200Machine Types: 3724, 3808, 3809, 3815, 3817, 3824, 3826, and 3836

Strona 2

Important:All caution and danger statements in this documentation begin with a number. Thisnumber is used to cross reference an English caution or dan

Strona 3

1 Power supply retaining screws2 Power supply assembly7. If you are instructed to return the power supply, follow all packaging instructions,and u

Strona 4

1 Power supply retaining screws2 Power supply assembly2. While you support the power supply cage, install the three screws that securethe power su

Strona 5 - Contents

1 Power supply support bracket2 Power supply release tab5. Install the side cover (see “Installing the side cover” on page 134).6. Lock the side c

Strona 6

4. If you are instructed to return the hot-swap fan, follow all packaging instructions,and use any packaging materials that are supplied to you for sh

Strona 7 - Contents v

3. Press down on the fan until it locks into place; then, close the fan handle to thelocking position.4. Install the side cover (see “Installing the s

Strona 8

1 Power supply2 Power-supply handle6. Remove the air baffle (see “Removing the air baffle” on page 44).7. Locate the DIMM connector that contains

Strona 9

88 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Strona 10

1 DIMM 1 (reserved) 9 DIMM 9 (reserved)2 DIMM 2 10 DIMM 103 DIMM 3 11 DIMM 114 DIMM 4 (reserved) 12 DIMM 12 (reserved)5 DIMM 5 13

Strona 11 - Safety ix

supported options for the server, see http://www.lenovo.com/thinkserver; then,select your country and navigate to the list of options for the server.–

Strona 12

Note: The amount of usable memory is reduced depending on the systemconfiguration. A certain amount of memory must be reserved for systemresources. To

Strona 13 - Safety xi

Statement 1:DANGERElectrical current from power, telephone, and communication cables ishazardous.To avoid a shock hazard:v Do not connect or disconnec

Strona 14

The following table lists the installation sequence for installing DIMMs inmemory-mirroring mode.Table 9. Memory-mirroring mode DIMM population sequen

Strona 15 - Safety xiii

1 Power supply2 Power-supply handle4. Remove the air baffle (see “Removing the air baffle” on page 44).5. Locate the DIMM connectors on the system

Strona 16

8. Turn the DIMM so that the DIMM keys align correctly with the connector.1 DIMM2 Retaining clip9. Insert the DIMM into the connector by aligning

Strona 17 - Safety xv

1 Power supply support bracket2 Power supply release tab12. Install the side cover (see “Installing the side cover” on page 134).13. Lock the side

Strona 18

1 Rear adapter-retention bracket2 Adapter3 Front adapter-retention bracket8. If the adapter is not being replaced, install an expansion-slot cov

Strona 19 - Chapter 1. Introduction

for x4 and x8 adapters. These same rules apply to the other PCI slots also.Check the information that comes with your adapter for compatibility inform

Strona 20

Note: Do not allow the server to fall over.4. Follow the cabling instructions that come with the adapter to set jumpers orswitches, if there are any.

Strona 21 - Related documentation

1 Adapter2 Rear adapter retention bracket3 Front adapter retention bracket8. Connect all required cables to the adapter. Route cables so that th

Strona 22

v The first microprocessor must always be installed in microprocessor socket 1.v When one microprocessor is installed, a heat sink filler is not requi

Strona 23

1 DIMM 9 (reserved) 15 DIMM 22 DIMM 10 16 DIMM 1 (reserved)3 DIMM 11 17 Battery4 DIMM 12 (reserved) 18 PCI extender card connector5

Strona 24

Statement 2:CAUTION:When replacing the lithium battery, use only a battery recommended by themanufacturer. If your system has a module containing a li

Strona 25 - Features and technologies

4. Remove the air baffle (see “Removing the air baffle” on page 44).5. Remove the fan cage assembly (see “Removing the fan cage assembly” onpage 46).6

Strona 26

c. Rotate the microprocessor release latch on the microprocessor socket fromthe closed and locked position to the fully open position.Attention:v Do n

Strona 27 - Specifications

1 Thermal grease2 Heat sinka. Make sure that the heat-sink release lever is in the open position.b. Remove the plastic protective cover from the b

Strona 28

e. Tilt the heat sink slightly to the side and slide the heat sink flangeunderneath the flange of the heat sink retainer bracket.f. Press down firmly

Strona 29

5. Disconnect any cables connected to the adapter.Attention: To avoid breaking the retaining clips or damaging theServeRAID-BR10i adapter connector, o

Strona 30 - EasyManage

1 ServeRAID-BR10i controller2 PCI slot 18. Press the ServeRAID-BR10i adapter firmly into the connector on the systemboard.9. Rotate the power-supp

Strona 31

11. Remove the fan cage assembly (see “Removing the fan cage assembly” onpage 46).12. Connect the configuration signal cable. See “Power and signal ca

Strona 32

slots on the bottom of the chassis underneath the fan cage assembly; then,connect it to the ServeRAID-BR10i SAS/SATA controller as shown in thefollowi

Strona 33 - Front view

1 Adapter connector2 Signal cable14. Reinstall the front fan cage assembly. Align the front fan cage assembly overthe fan cage assembly slot and w

Strona 34

1 Power supply support bracket2 Power supply release tabIf you have other options to install or remove, do so now. Otherwise, Go to“Completing the

Strona 35 - 1 Power-on LED 6 USB 1

Statement 3:CAUTION:When laser products (such as CD-ROMs, DVD drives, fiber optic devices, ortransmitters) are installed, note the following:v Do not

Strona 36

Installing the optional ServeRAID-MR10i SAS/SATA controllerThe optional ServeRAID-MR10i SAS/SATA controller can be installed only in itsdedicated conn

Strona 37 - Operator information panel

1 ServeRAID adapter2 Battery carrier3 Battery4 Connector for battery carrierb. Press the battery carrier into the connector on the ServeRAID a

Strona 38 - EasyLED diagnostic panel

1 ServeRAID-MR10i controller2 PCI slot 110. Press the ServeRAID-MR10i adapter firmly into the connector on the systemboard.11. Rotate the power-su

Strona 39

1 Adapter connector for drives 0-3 signal cable2 Signal cable for drives 0-3The following illustration shows the connectors on the controller to w

Strona 40

1 Signal cables for drives 4-72 Adapter connector for drives 4-7 signal cable3 Signal cable for drives 0-34 Adapter connector for drives 0-3 s

Strona 41

1 Adapter connector2 Signal cable16. Reinstall the front fan cage assembly. Align the front fan cage assembly overthe fan cage assembly slot and w

Strona 42

1 Power supply support bracket2 Power supply release tab19. If you have other options to install or remove, do so now.20. Replace the side cover (

Strona 43

2. Turn off the server and peripheral devices, and disconnect the power cordsand all external cables.Attention: To avoid breaking the retaining clips

Strona 44 - Rear view

c. Secure the battery carrier to the ServeRAID adapter with the screws thatcame with the battery pack.10. Turn the ServeRAID-MR10is adapter so that th

Strona 45

1 Power supply2 Power-supply handle13. Remove the air baffle (see “Removing the air baffle” on page 44).14. Remove the front fan cage assembly (se

Strona 46

Statement 4:≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb)CAUTION:Use safe practices when lifting.Statement 5:CAUTION:The power control button

Strona 47

1 Adapter connector for drives 0-3 signal cable2 Signal cable for drives 0-3The following illustration shows the connectors on the controller to w

Strona 48

1 Signal cable for drives 4-72 Adapter connector for drives 4-7 signal cable3 Signal cable for drives 0-34 Adapter connector for drives 0-3 si

Strona 49

1 Adapter connector2 Signal cable17. Reinstall the front fan cage assembly. Align the front fan cage assembly overthe fan cage assembly slot and w

Strona 50

1 Power supply support bracket2 Power supply release tab21. If you have other options to install or remove, do so now.22. Replace the side cover (

Strona 51 - System-board LEDs

Do not insert a memory DIMM in this connector.This DIMM slot is not supported in this model.Do not insert a memory DIMM in this connector.This DIMM sl

Strona 52

Do not insert a memory DIMM in this connector.This DIMM slot is not supported in this model.Do not insert a memory DIMM in this connector.This DIMM sl

Strona 53 - Turning off the server

5. Rotate the power-supply cage assembly out of the chassis. Lift up thepower-supply cage handle and pull the power-supply cage assembly all theway up

Strona 54

9. Disconnect the control-panel assembly cable from the system board, noting therouting of the cable (see “System-board internal connectors” on page 2

Strona 55 - Installation guidelines

1 Power supply support bracket2 Power supply release tab8. Close the bezel.9. Install the side cover (see “Installing the side cover” on page 134)

Strona 56 - System reliability guidelines

1 Bezel2 Hinge assembly3 Retention tabs2. Push the hinges into the holes on the chassis until they snap into place.3. If however, the bezel was

Strona 57

Statement 8:CAUTION:Never remove the cover on a power supply or any part that has the followinglabel attached.Hazardous voltage, current, and energy l

Strona 58 - Opening the bezel

1 Sliding hinge mount2 Hinge pin3 Hinge assemblyb. Align the sliding hinge mount with the hinge pin on the hinge assembly onthe chassis.c. Press

Strona 59

1 Air baffle pinch tab2 Air baffle2. Lower the air baffle into the server until the air baffle is seated firmly.3. Press the power supply release

Strona 60

5. Lock the side cover.6. Reconnect the external cables and power cords; then, turn on the attacheddevices and turn on the server.Installing the side

Strona 61 - Removing the side cover

If the server cables and connector panel have color-coded connections, match thecolor of the cable end with the color of the connector. For example, m

Strona 62 - Removing the air baffle

Some options have device drivers that you must install. For information aboutinstalling device drivers, see the documentation that comes with each opt

Strona 63

Chapter 6. Configuring the serverThe following configuration programs and utilities come with the server:v Setup UtilityThe UEFI (formerly BIOS) Setup

Strona 64

v Advanced Settings Utility (ASU) programUse this program as an alternative to the Setup Utility for modifying UEFI settingsand IMM settings. Use the

Strona 65 - 1 Fan cage assembly

Select this choice to view the system-board identifier, the revision level orissue date of the firmware, the integrated management module anddiagnosti

Strona 66

specify whether to use the static IP address or have DHCP assign the IMMIP address; save the network changes.- Reset IMM to DefaultsSelect this choice

Strona 67

v User SecuritySelect this choice to set, change, or clear passwords. See “Passwords” for moreinformation.This choice is on the full and limited Setup

Strona 68

Statement 13:DANGEROverloading a branch circuit is potentially a fire hazard and a shock hazardunder certain conditions. To avoid these hazards, ensur

Strona 69

password has access to only the limited Setup Utility menu; the user can set,change, and delete the power-on password, if the system administrator has

Strona 70 - 2 Power-supply release tab

Table 11. RAID configuration utilities (continued)RAID configurationutility Description LocationWhere to find moreinformationMegaRAID BIOSConfiguratio

Strona 71 - 2 Hinge pins

v Hard disk drive capacities affect how you create arrays. The drives in an arraycan have different capacities, but the RAID controller treats them as

Strona 72 - Removing the battery

3. Select the type of array that you want to create.4. In the RAID Disk column, use the Spacebar or Minus (-) key to select [Yes](select) or [No] (des

Strona 73 - Installing the battery

Physical View or Logical ViewSelect this to toggle between the Physical View and Logical View.EventsFrom this view, you can display the system events

Strona 74 - 1 Positive (+) side

menu and click Change. The Operations panel lists operations that can beperformed on the virtual disk. Select the operation and click Go. Then choose

Strona 75

Configuring RAIDThe RAID configuration feature that is part of the EasyStartup program enables youto view and change RAID settings for supported RAID

Strona 76

You will then see one or more reminders about configuring storage devices, andthen you will be presented with the Lenovo License Agreement. Read the l

Strona 77 - Removing a DVD drive

v Install applications: This task enables you to run custom commands or scriptsat the end of the installation process. It also facilitates the install

Strona 78

Enabling the Broadcom Gigabit Ethernet Utility programThe Broadcom Gigabit Ethernet Utility program is part of the server firmware. Youcan use it to c

Strona 79

Statement 26:CAUTION:Do not place any object on top of rack-mounted devices.This server is suitable for use on an IT power-distribution system whose m

Strona 80 - Installing a DVD drive

3. From Family list, select ThinkServer TD200, and click Continue.4. Click Downloads and drivers to download firmware updates.Download the latest firm

Strona 81

To download the server firmware update package from the World Wide Web, do thefollowing:Note: Changes are made periodically to the Lenovo Web site. Th

Strona 82 - 3 Optical drive rails

6. Reinstall the server cover (see “Installing the side cover” on page 134); then,reconnect all power cords.7. Restart the server. The power-on self-t

Strona 83 - 1 Optical drive power cable

2. Remove any devices that you added recently and restart the server.3. If the problem remains, go to the Setup utility and select Load DefaultSetting

Strona 84

v Boot sequence manipulation.The IMM also provides the following remote server management capabilities:v Command-line interface (IPMI Shell)The comman

Strona 85

1. Install the virtual media key into the dedicated slot on the system board (see“System-board option connectors” on page 30).2. Turn on the server.No

Strona 86 - 2 Tape drive

Diagnostics programs and messagesThe diagnostics programs are the primary method of testing the major componentsof the server. As you run the diagnost

Strona 87

Note: The DSA Preboot diagnostics program might appear to be unresponsivefor an unusual length of time when you start the program. This is normalopera

Strona 88

Installing EasyManage softwareYou can install the ThinkServer™EasyManage Core Server program from theEasyManage CD or you can download and install the

Strona 89 - 4 Hard disk drive

Note: This specific version is required.6. Use Windows Update to install all available critical updates.7. Launch the EasyManage installation.8. After

Strona 90 - 5 Hard disk drive

xvi ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Strona 91

v Static Contentv ASP.NETv ASPv CGIv Server Side Includesv Windows Authenticationv IIS 6 Metabase CompatibilityNote: When you select ASP.Net or ASP, a

Strona 92

Chapter 7. TroubleshootingThis chapter describes the diagnostic tools that are available to help you solveproblems that might occur in the server.If y

Strona 93

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 94 - 2 Drive-bay EMC shield

General problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardwar

Strona 95

Intermittent problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Ha

Strona 96

Memory problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware

Strona 97 - Removing a power supply

Microprocessor problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the

Strona 98

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 99

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 100 - Installing a power supply

Power problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware

Strona 101 - 2 Power supply assembly

Chapter 1. IntroductionThis Installation and User Guide contains information and instructions for setting upyour ThinkServer TD200 Types 3724, 3808, 3

Strona 102 - Removing a hot-swap fan

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 103 - Installing a hot-swap fan

Software problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardwa

Strona 104 - Removing a memory module

clear the CMOS memory; see “System-board switches and jumpers” on page 31. Ifyou suspect that the server firmware is damaged, see “Recovering the serv

Strona 105 - 2 Power-supply handle

1. Make sure that external SCSI devices are turned on before you turn on theserver.2. Make sure that the cables for all external SCSI devices are conn

Strona 106

– The Ethernet transmit/receive activity LED is lit when the Ethernet controllersends or receives data over the Ethernet network. If the Ethernettrans

Strona 107 - Installing a memory module

v Integrated management module (IMM) event log: This log contains a supersetof IMM, POST, and systems-management interrupt (SMI) information that is i

Strona 108 - 12 Dual-rank DIMMs 4 GB 48 GB

Table 12. Methods for viewing event logsCondition ActionThe server is not hung and is connected to anetwork.Run Portable or Installable DSA to view th

Strona 109

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 110

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 111

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 113 - Removing an adapter

The model number and serial number are on the lower right side of the bezel. 1Note: The illustrations in this document might differ slightly from yo

Strona 114 - Installing an adapter

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 115

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 116

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 117 - 1 Adapter

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 118

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 119

Appendix A. Getting help and technical assistanceIf you need help, service, or technical assistance or just want more informationabout Lenovo products

Strona 120

Calling for serviceDuring the warranty period, you can get help and information by telephone throughthe Customer Support Center.These services are ava

Strona 121 - 3 Notches

Service methods and procedures vary by country, and some services might not beavailable in all countries. International Warranty Service is delivered

Strona 122

190 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Strona 123 - 2 Power supply release tab

Appendix B. NoticesLenovo may not offer the products, services, or features discussed in this documentin all countries. Consult your local Lenovo repr

Strona 124

v Danger: These statements indicate situations that can be potentially lethal orextremely hazardous to you. A danger statement is placed just before t

Strona 125 - 2 PCI slot 1

estimated through extrapolation. Actual results may vary. Users of this documentshould verify the applicable data for their specific environment.Trade

Strona 126

Maximum memory might require replacement of the standard memory with anoptional memory module.Lenovo makes no representations or warranties with respe

Strona 127

Remarque : Cette marque s’applique uniquement aux pays de l’Union Européenneet à la Norvège.L’etiquette du système respecte la Directive européenne 20

Strona 128 - 2 Signal cable

Recycling statements for JapanBattery return programThis product may contain a lithium or lithium ion battery. Consult your user manualor service manu

Strona 129

For the European Union:Notice: This mark applies only to countries within the European Union (EU).Batteries or packaging for batteries are labeled in

Strona 130

Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne§2derBildschirmarbeitsverordnung geeignet.Electronic emission noticesFederal

Strona 131 - 3 Battery

failure to satisfy the protection requirements resulting from a non-recommendedmodification of the product, including the fitting of non-Lenovo option

Strona 132

Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022Klasse A.Nach der EN 55022: “Dies ist eine Einrichtung der Klasse A. Diese Einrich

Strona 133

Korea Class A warning statement200 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Strona 134

IndexAABR, automatic boot failure recovery 154acoustical noise emissions 9, 11adapterhot-plug devices 106installing 97hot-plug 106removing 95requireme

Strona 135

4 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Strona 136

Ddanger statements 2DASD LED 22data rate, Ethernet 151deassertion event, system-event log 176diagnostics program 8DIMM installation sequencefor memory

Strona 137

firmware updates 1firmware, serverstarting the backup 152firmware, server, recovering 152firmware, updating 151formattinghard disk drive 144front USB

Strona 138

LEDsDVD drive activity 18EasyLED; diagnostics 25Ethernet link status 27Ethernet transmit/receive activity 27hard disk drive activity 17hot-swap hard d

Strona 139

password, power-onclear 141set 141passwords 141PCIbus LED 21PCI extender cardone-slot 34two-slot 34pointing-device problems 166portsEthernet 27serial

Strona 140

safety information (continued)Statement 3 xiStatement 4 xiiStatement 5 xiiStatement 8 xiiisystem reliability considerations 38when the server is on 38

Strona 141

TÜV gloss statement 196two-slotPCI extender card 34UUEFIboot recovery jumper 153UEFI update failurerecovery 152undetermined problems 173United States

Strona 142

208 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Strona 144 - 4 Retention tab

Part Number: 44W2344Printed in USA(1P) P/N: 44W2344

Strona 145

Chapter 2. Server setup roadmapThe installation process varies depending on the configuration of the server when itwas delivered. In some cases, the s

Strona 146

6 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Strona 147 - 2 Control panel assembly

Chapter 3. What is included with your serverThe TD200 server package includes the server, power cords, and the ThinkServerDocumentation DVD.1 Server

Strona 148 - Closing the bezel

Note: The server does not support Disk Operating System (DOS).v Preboot diagnostics programThe preboot diagnostics programs are stored on the integrat

Strona 149 - 3 Retention tabs

Some models support memory mirroring. Memory mirroring replicates and storesdata on two pairs of DIMMs within two channels (channel 0 and 1)simultaneo

Strona 150 - Installing the air baffle

Table 1. Features and specificationsMicroprocessor:v Supports up to two Intel®Pentium®dual-core or quad-core microprocessors(one installed) with integ

Strona 151 - 2 Air baffle

Table 1. Features and specifications (continued)Drives (depending on the model):v Optical drives: SATAv Hard disk drives: SAS and SATADrive bays (depe

Strona 152 - Connecting the cables

ThinkServer TD200 Types 3724, 3808, 3809, 3815,3817, 3824, 3826, 3836Installation and User Guide

Strona 153

Table 1. Features and specifications (continued)Up to eight expansion slots (dependingon the model):v Six expansion slots on the systemboard– Four PCI

Strona 154 - Connecting external devices

Reliability, availability, and serviceabilityThree important server design features are reliability, availability, and serviceability(RAS). The RAS fe

Strona 155

v Upgradeable microcode for POST, server firmware, and read-only memory(ROM) resident code, locally or over a LANv Vital product data (VPD); includes

Strona 156 - Setup Utility menu choices

Chapter 4. Server controls, LEDs, and powerThis section describes the controls, light-emitting diodes (LEDs), and connectors onthe front and rear of t

Strona 157

1 Power-on LED 7 DVD-eject button2 Power-control button 8 Hard disk drive activity LED (green)3 Hard disk drive activity LED 9 Hard disk d

Strona 158

1 Power-on LED 6 USB 12 Power-control button 7 DVD-eject button3 Hard disk drive activity LED 8 Simple-swap hard disk drive4 System-erro

Strona 159 - Passwords

An LED on the system board might also be lit to help isolate the error.Detailed troubleshooting information is in the Hardware MaintenanceManual.USB c

Strona 160 - Configuring RAID controllers

Operator information panelThe following illustration shows the LEDs on the operator information panel on thefront of the server.1 System power-on LE

Strona 161

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 162 - Formatting a hard disk drive

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 163 - Starting the WebBIOS utility

Note:Note: Before using this information and the product it supports, read the general information in Appendix B, “Notices,” on page 191and the Warran

Strona 164

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 165 - Using the EasyStartup DVD

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 166 - EasyStartup overview

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 167

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Strona 168

Rear viewThe following illustration shows the LEDs and connectors on the rear of the server.1 Power cord connector 10 USB 12 Ethernet transmit/r

Strona 169 - Updating the firmware

Power-error (Fault) LEDWhen this amber LED is lit, it indicates that the power supply has failed.For any other combination of LEDs, see the Hardware M

Strona 170

System-board internal connectorsThe following illustration shows the internal connectors on the system board.1 Main power 12 Reserved2 Reserved

Strona 171 - 3 SW6 switch block

System-board external connectorsThe following illustration shows the external input/output (I/O) connectors on thesystem board.1 Power connector 6

Strona 172 - Three boot failure

System-board option connectorsThe following illustration shows the system-board connectors for user-installableoptions.1 DIMM 9 (reserved) 15 DIMM

Strona 173

System-board switches and jumpersThe following illustration shows the switches and jumpers on the system board.1 UEFI boot recovery jumper (JP8)2

Strona 174

ContentsSafety ...viiChapter 1. Introduction ...1Notices and statements in this document...2R

Strona 175

Table 2. System-board jumpers (continued)Jumper number Jumper name Jumper settingJP6 UEFI boot recovery jumperv Pins 1 and 2: Normal(default) - Loads

Strona 176

Important:1. Before you change any switch settings or move any jumpers, turn off the server,then, disconnect all power cords and external cables. Read

Strona 177

1 Microprocessor mismatchLED9 PCI slot 6 error LED2 Microprocessor 2 error LED 10 PCI slot 5 error LED3 DIMMs 9-18 error LEDs 11 PCI slot

Strona 178 - Installation order

Server power featuresWhen the server is connected to an ac power source but is not turned on, theoperating system does not run, and all core logic exc

Strona 179

12The server can be turned off in any of the following ways:v You can turn off the server from the operating system, if your operating systemsupports

Strona 180

Chapter 5. Installing optional devices and replacing customerreplaceable unitsImportant: Before you install optional hardware, make sure that the serv

Strona 181 - Chapter 7. Troubleshooting

v You do not have to turn off the server to install or replace hot-swap fans andhot-swap drives.v Blue on a component indicates touch points, where yo

Strona 182 - Diskette drive problems

v Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wristwatches.v Remove items from your shirt pocket, such as pens and pencils,

Strona 183 - Hard disk drive problems

Major components of the serverThe following illustration shows the major components in the server (depending onthe server model). The illustrations in

Strona 184 - Intermittent problems

Note: You must unlock the side cover to open or remove the bezel. When youlock the server side cover, it locks both the cover and the bezel.3. Remove

Strona 185 - Memory problems

Removing and installing drives ...57Removing a DVD drive ...59Installing a DVD drive ...62Removing

Strona 186 - Monitor or video problems

1 Bezel2 Hinge assembly3 Retention tabsNote: The bezel will also disengage from the chassis hinges if you rotate thebezel beyond 180° or if exce

Strona 187

4. From inside of the top section of the bezel door, slide the blue tab up to unlockthe bezel media door (slide the tab down when you want to lock it)

Strona 188 - Optional-device problems

1 Cover release latch2 Latch3 Left-side coverTo replace the side cover, see “Installing the side cover” on page 134.Attention: For proper coolin

Strona 189 - Power problems

1 Power supply2 Power-supply handle8. Remove the air baffle assembly. Press the blue tab (on top of the fan cage) onthe air baffle assembly to the

Strona 190 - Serial port problems

Removing the fan cage assemblyAttention:v Replace a hot-swap fan within 30 seconds of removal.v To ensure proper cooling and airflow, do not operate t

Strona 191 - Solving undetermined problems

1 Fan cage assembly2 Fan cage assembly release buttons8. If you are instructed to return the fan cage, follow all packaging instructions, anduse a

Strona 192 - Solving SCSI problems

1 Fan cage assembly2 Fan cage assembly release buttons2. Slide the fan cage into the chassis and press firmly until the fan cage is seatedfirmly i

Strona 193 - Solving power problems

1 Power supply support bracket2 Power supply release tab5. Install the side cover (see “Installing the side cover” on page 134).6. Lock the side c

Strona 194 - Event logs

1 Power supply2 Power-supply handle5. Remove the air baffle (see “Removing the air baffle” on page 44).6. Remove the fan cage assembly (see “Remov

Strona 195

9. Press the release tab on the front USB housing; then, tilt the top of thehousing away from the chassis and lift the housing out of the chassis.10.

Strona 196 - POST error codes

EasyStartup overview ...148Installing your operating system without using EasyStartup ...150Using the Boot Manager program ...

Strona 197

6. Install the fan cage assembly (see “Installing the fan cage assembly” on page47).Note: Make sure that all cables are routed so that they are not da

Strona 198

4. Open the rear adapter retention bracket.5. Press the rear adapter retention bracket and release the top hinge point; then,release the other hinge p

Strona 199

4. Install the side cover (see “Installing the side cover” on page 134).5. Lock the side cover, if necessary.6. Reconnect the external cables and powe

Strona 200

Statement 2:CAUTION:When replacing the lithium battery, use only a battery recommended by themanufacturer. If your system has a module containing a li

Strona 201

v The lithium battery must be handled correctly to avoid possible danger. If youreplace the battery, you must adhere to the following instructions.v Y

Strona 202

Note: You must wait approximately 1 to 3 minutes after you connect the powercord of the server to an electrical outlet before pressing the power-contr

Strona 203

1 Bay 12 Bay 23 Bay 34 Bay 45 Bay 56 Bay 67 Bay 7The following illustration shows the location of the drive bays in the 3.5-inchsimple-s

Strona 204

1 Bay 12 Bay 23 Bay 34 Bay 45 Bay 56 Bay 67 Bay 7The following notes describe the types of drives that the server supports and otherinfo

Strona 205 - Using the documentation

1. Read the safety information (see “Safety” on page vii and “Installationguidelines” on page 37).2. Turn off the server and all attached devices; the

Strona 206 - Using other services

1 Fan cage assembly2 Fan cage assembly release buttons8. Disconnect the power and signal cables from the drive that is to be removed.9. Press and

Strona 207 - Lenovo product service

Lenovo product service ...189Appendix B. Notices ...191Trademarks...192Important notes ...

Strona 208

Installing a DVD driveTo install a DVD drive, do the following:1. If you are replacing a drive, make sure that:v You have all the cables and other equ

Strona 209 - Appendix B. Notices

1 Power supply2 Power-supply handle3. Remove the air baffle (see “Removing the air baffle” on page 44).4. Remove the fan cage assembly. Press in o

Strona 210 - Important notes

5. Touch the static-protective package that contains the new DVD drive to anyunpainted metal surface on the server; then, remove the DVD drive from th

Strona 211 - Appendix B. Notices 193

1 Optical drive power cable2 SATA optical drive signal cable10. Install the fan cage assembly (see “Installing the fan cage assembly” on page47).1

Strona 212 - Hazardous Substances

1 Power supply support bracket2 Power supply release tab13. Close the bezel.14. Install the side cover (see “Installing the side cover” on page 13

Strona 213 - Battery return program

and set it aside.8. Disconnect the tape drive cable from the system board.9. Remove the screws that secure the tape drive 1 to the server.10. Gently

Strona 214

1 EMC shield2 Tape drive5. If the tape drive comes with screws, secure the tape drive to the chassis withthe supplied screws.6. Connect one of the

Strona 215 - Appendix B. Notices 197

1 SATA optical drive power cable2 USB signal cable connector3 USB signal cable4 SATA optical drive power cable (SATA-to-traditional power conv

Strona 216

Removing a 2.5-inch hot-swap hard disk driveAttention: To maintain proper system cooling, do not operate the server for morethan 10 minutes without ei

Strona 217 - Appendix B. Notices 199

1 Release latch2 Drive tray handle (in open position)3 Drive tray4 Hard disk drive7. If you are instructed to return the 2.5-inch hot-swap har

Strona 218

SafetyBefore installing this product, read the Safety Information.Antes de instalar este produto, leia as Informações de Segurança.Pred instalací toho

Strona 219

1. Read the safety information (see “Safety” on page vii and “Installationguidelines” on page 37).2. Touch the static-protective package that contains

Strona 220

Removing a 3.5-inch hot-swap hard disk driveAttention: To maintain proper system cooling, do not operate the server for morethan 10 minutes without ei

Strona 221 - Index 203

1 Hot-swap hard disk drive2 Drive tray3 Drive tray handle (in open position)6. If you are instructed to return the 3.5-inch hot-swap hard disk d

Strona 222

6. Check the hard disk drive status indicator to make sure that the hard disk driveis operating correctly.After you replace a failed hard disk drive,

Strona 223 - Index 205

1 Filler panels2 Drive-bay EMC shield3 Tab4 Hard disk drive6. Pull the loops of the drive assembly that is to be removed toward each other;the

Strona 224

1 Filler panels2 Drive-bay EMC shield3 Tab4 Hard disk drive3. Pull the loops of the drive assembly toward each other; then, carefully slide th

Strona 225 - Index 207

Table 4. IDs for the four-bay 3.5-inch hot-swap drive models (continued)Drive bay number IDDrive bay 5 1Drive bay 6 2Drive bay 7 3Table 5. IDs for the

Strona 226

– The 2.5-inch hot-swap SAS and hot-swap SATA models come with thefollowing cables to provide signal and power to the hot-swap SAS/SATAdrives:- Two si

Strona 227

CAUTION:Never remove the cover on a power supply or any part that has the followinglabel attached.Hazardous voltage, current, and energy levels are pr

Strona 228 - (1P) P/N: 44W2344

1 Power supply2 Power-supply handle5. Disconnect the cables from the power supply to the system board and allinternal components. Be sure to make

Komentarze do niniejszej Instrukcji

Brak uwag