Lenovo ThinkServer RD210 Instrukcja Użytkownika Strona 4

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 7
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 3
Lift the locking levers 1 on the slide rails and
push the server 2 all the way into the rack until it
clicks into place.
The cable-management arm can be installed on
either side of the server. This document shows it
being installed on the left side. To install the
cable-management arm on the right side, follow the
instructions and install the hardware on the
opposite side.
Connect one end of the support arm 1 to the
same slide rail to which you plan to attach the
cable-management arm so that you can swing the
other end of the support arm 2 toward the rack.
Install the L-shaped cable-management stop bracket
1 on the unattached end of the support arm. Turn
the bracket 2 to secure it to the support arm.
To attach the other side of the support arm to the
backside of the slide rail, pull the pin out 1, and
then slide the bracket 2 into the slide rail.
4
Przeglądanie stron 3
1 2 3 4 5 6 7

Komentarze do niniejszej Instrukcji

Brak uwag