1SAS-connector-statusLEDs
StatusColor
Description
OnGreenTheSASconnectorisinuse,butnodataisbeingtransferred.
Blinking
GreenTheSASconnectorisactiveanddataisbeingtransferred.
On
Amber
TheSASconnectorhaspotentialerrors.
Off
None
TheSASconnectorisnotinuseorisworkingnormally.
Note:WhenaSAS-connector-statusLEDindicatespotentialerrors,checkthesystem-statusLEDsonthe
serverthatthestoragearrayisconnectedtoforconfirmation.
2RearI/Omodulepower-statusLED
Status
Description
OnTherearI/Omoduleisturnedon.
OffTherearI/Omoduleisturnedoff.
3RearI/OmodulestatusLED
Status
Description
OnTherearI/Omodulehaspotentialerrors.
OffTherearI/Omoduleisworkingnormally.
4Debugconnector
Usethedebugconnectortoupdatethefirmwareofthestoragearrayanddiagnoseproblems.SeeChapter5
“Updatingthefirmware”onpage29and“Usingthecommandlineinterface”onpage59.
5SAS-outconnector
UsetheSAS-outconnectortoconnectyourstoragearraytoanotherstoragearrayincascadingmode.
See“Connectingthestoragearrays”onpage19.
6SAS-inconnector
UsetheSAS-inconnectortoconnectyourstoragearraytoaserveroranotherstoragearray.See
“Connectingthestoragearrays”onpage19.
Drive-statusLEDs
EachdrivehastwostatusLEDsonthefront.
Figure10.StatusLEDson3.5-inchdrives